This refurbished Agilent G6130A Quadrupole Mass Spectrometer with Agilent 1200 Series HPLC System is in good condition.
High-performance design features
• Orthogonal-flow sprayer with pneumatic nebulizer – enhances sensitivity across a wide range of LC conditions and reduces maintenance requirements.
• High-capacity solvent drying system – reduces chemical noise and permits the analysis of thermally-sensitive compounds through user control of gas flow rate and gas temperature.
• Dielectric platinum-plated capillary – enhances sensitivity, permits independent optimization of the spray chamber and ion optics, and allows dynamic optimization of in-source fragmentation.
• Air-cooled turbomolecular pump – provides fast startup and a small footprint, and eliminates the need for cooling water. Single, split-flow turbo pump enhances performance and increases reliability.
• Fraction collection capability – can monitor and trigger the collection of fractions based on mass, an analog signal input, or time. For mass-based determination, up to 16 m/z values can be monitored. Requires optional I/O Accessory Module.
Mass Range | 6130 Quad: m/z 2 – 3000 |
Mass Accuracy | ± 0.13 u within the calibrated mass range in scan mode |
Mass Axis Stability | The mass drift does not exceed the larger absolute value of ± 0.1 Da or ± 100 ppm of measured mass over a 12 hour period at constant temperature ± 3 degrees centrigrade. |
Scan Speed | 6130 Quad: 2500 u/s standard mode, 5250 u/s fast scan mode |
SIM Sensitivity | • ESI at 400 µ/min or APCI at 1000 µ/min
• Selected ion monitoring of m/z 609.3 • Positive ionization |
6130 and 6140 Quad: 1 pg reserpine, 100:1 RMS (20:1 peak-to-peak) | |
Scan Sensitivity* | • ESI at 400 µ/min or APCI at 1000 µ/min
• Scan range m/z 100 – 650 • Scan speed 2500 u/s • Extracted ion at m/z 609.3 • Positive ionization |
6130 and 6140 Quad: 50 pg reserpine, 100:1 RMS (20:1 peak-topeak) | |
Flow Rate | ESI: Up to 1.0 ml/min water without a flow splitter
APCI: Up to 1.5 ml/min water without a flow splitter |
Multisignal acquisition (6120, 6130 and 6140 Quad only) | Ability to cycle through four acquisition modes on a scan-by-scan basis within a single run. Up to four analysis modes can be viewed in the software window and can be linked together to facilitate processing and analysis. Modes of operation: positive/negative polarity switching, variable fragmentor voltage selection, and concurrent SIM/scan. |
Operating Conditions | Temperature range: 15 °C to 35 °C (59 °F to 95 °F) Relative humidity: less than 95 % (non-condensing) |
Dimensions** Height: 65 cm (26 in) Width: 39 cm (15 in) Depth: 75 cm (29 in W | Height: 65 cm (26 in)
Width: 39 cm (15 in) Depth: 75 cm (29 in Weight: 50 kg (110 pounds) **Approximate maximum cabinet dimensions with G1947A APCI source attached but without external mechanical pump. Height and width slightly less with G1948A ESI source. |
Agilent 1200 system includes:
- G1312A Binary Pump
- G1379B degasser with solvent tray
- G1367B HiP ALS autosampler
- G1316 A/B/C column compartment with switch valve installed
- PC with data
System comes with a 90 day warranty.