Features
The ICS-5000 Reagent-Free™ IC (RFIC™) system with Eluent Generation is the world’s first capillary IC system. Developed with flexibility, modularity, and ease-of-use in mind, the ICS-5000 combines the highest sensitivity with convenience.
With the ability to analyze samples at capillary, microbore, or standard flow rates (or any combination of two, in a dual system), the system is simply Always Ready. The wide variety of ICS-5000 modules allows you to configure an ion chromatography system designed specifically to provide the solutions you need.
The Dionex ICS-5000 is the first system with an all-PEEK flow path capable of operating continuously at 5000 psi. Reagent-Free HPIC systems redefine the way ion chromatography is performed.
This Dionex Ics-5000 Ion Chromatography System includes:
- Dionex ICS-5000 Dual Pump (DP)
- Dionex ICS-5000 Eluent Generator (EG)
- Dionex ICS-5000 Detector/Chromatography Module
- Dionex AS-50 Autosampler
- A 90-day warranty
This refurbished Dionex Ics-5000 Ion Chromatography System is in great condition. It has been tested at SpectraLab Scientific.
Dionex ICS-5000 Dual Pump(DP)
Specifications | |
Type | Dual-piston (in series), microprocessor-controlled, constant-stroke, variable-speed, patented isokinetic Eluent Precompression |
Construction | Chemically inert, metal-free PEEK pump heads and flow path; compatible with aqueous eluents from pH 0–14 and reversed-phase solvents |
Pressure Range | 0–41 MPa (0–6000 psi) |
Flow Rate Range | Analytical: 0.000–10.000 mL/min with settable flow increments at 0.001 mL/min
Capillary: 0.001–3.000 mL/min with settable flow increments at 0.0001 mL/min |
Flow Rate Precision | <0.1% |
Flow Rate Accuracy | <0.1% at 14 MPa (2000 psi) |
Pressure Ripple | Analytical: < 1.0% at 1.0 mL/min typical
Capillary: < 0.2% (with damper) or < 1.0% (without damper) at 10 μL/min |
Pressure | None required |
Vacuum Degasser | Integrated degasser with 1 channel for isocratic pump or 4 channels for quaternary pump; optional |
Piston Seal Wash | Automatic operation, standard |
Gradient Formation | Quaternary low pressure (Analytical only) or electrolytic eluent generation at high pressure (Analytical and Capillary) |
RFIC-EG Gradients | Analytical: 0.1–100 mM
Capillary: 0.1–200 mM |
Gradient Profiles | Any combination of an unlimited number of linear, convex, and concave positive and negative gradient profiles |
Gradient Proportioning
Accuracy and Precision (Analytical only) |
±0.5% at 2 mL/min |
Gradient Mixing
(Analytical only) |
Passive mixers for 2 mm and 4 mm ID columns, Optional |
Eluent Generation | Eluent generation (RFIC-EG), optional |
Eluent On/Off Valve | Electrically-actuated, standard |
Leak Sensor | Optical, standard |
Dionex ICS-5000 Eluent Generator (EG)
Specification | |
Minimum and Maximum Eluent Concentrations | 0.01–100 mM (Analytical)
0.01–200 mM (Capillary) |
Flow Rates | 0.100–3.000 mL/min (Analytical)
0.001–0.030 mL/min (Capillary) |
Eluent Types | KOH, LiOH, NaOH Carbonate Carbonate/bicarbonate Carbonate with pH modifier MSA |
Maximum Operating Pressure | 35 MPa (5000 psi) |
Maximum Solvent Concentration | Cations: None Anions: 25% methanol |
Gradient Profiles | Standard—any combination of an unlimited number of linear, convex, and concave positive and negative gradient profiles |
Number of Cartridges Supported | Two—dual cartridge support |
Dionex ICS-5000 Detector/Chromatography Module
Specification | |
DC models: | Dual Temperature Model Only |
Dual Temperature Model: independent temperature control |
Upper Section Temp. Range: 10–40 °C Lower Section Temp. Range: 10–70 °C Temperature Accuracy: ± 0.5 °C Temperature Stability: ± 0.2 °C Temperature Precision: ± 0.2 °C |
Lower Zone: (Analytical) | Injection valves: 1 or 2 ea., 6 or 10 port Up to two column sets, 1–9 mm Maximum column length: 250 mm Precolumn heat exchangers: 2 |
Cap IC Cube: (Optional – but required for capillary chemistries) | 1 or 2 IC Cube™ modules hold the following: Injection Valves: Up to 2 (one per cube) high pressure valves, 4-port, 2 position EG Degasser Column and Guard Carbonate Removal Device Capillary Suppressor (See Suppressor section) IC Cubes and cartridges are customer installable with preformed tubing and color-coded labeling Capillary column heater 15 to 85 °C |
Automation Manager: (Optional) | Injection valves: Up to 2 ea., high pressure valves, either 6 or 10 port Low pressure valves: Up to 2 ea., PTFE, 2 or 3 way Reaction Coil Heater: Holds up to two reaction coils Temperature Range: 5 °C above DC, up to 80 °C |
Leak detection: | Optical leak sensor |
Dionex AS-50 Autosampler
Specification | |
Injections Per Vial | 1 to 99 |
Vial Sizes Available | 0.3 mL polymer vials (P/N 055428, package of 100)
1.5 mL glass vials (P/N 055427, package of 100) 10 mL PolyVials (P/N 055058, package of 100) |
Variable Volume Range | 1 to 100 µL in 0.1 µL increments
100 to 1000 mL in 1 µL increments |
Injection Loop Size | IC version: 25 µL standard; other sizes are available
HPLC version: 20 µL standard; other sizes are available |
Injection | Two-position, six-port, electrically-activated Rheodyne valve
IC version: PEEK with Tefzel® rotor seal HPLC version: Stainless steel with Vespel® rotor seal |
Column Switching | Two-position, ten-port, electrically-activated Rheodyne valve
IC version: PEEK with Tefzel rotor seal HPLC version: Stainless steel with Vespel rotor seal |
NOTE: Eluent generator cartridges are considered a consumables and we do not supply these. Since they are a method-dependent consumables, customers are responsible for obtaining their own eluent generator cartridges.