This Varian CP-3800 GC System comes with:
*Thermionic Specific Detector (TSD)
*Flame Ionization Detector (FID)
*CTC Combi Pal
*PC with Suitable software and all essential cables required for full operation
They are all in excellent condition. They have been tested at SpectraLab Scientific.
A 90 day warranty is included.
Specifications
Dimensions and Weights
-Size: 53 cm (h) x 66 cm (w) x 56 cm (d)
– Weight: 43 kg
Environmental Conditions
-Operating temperatures: 10°C to 40°C
-Operating humidity (relative): 5% to 95%
-Line voltage requirements: 101V, 120V, 230V (±10% nominal)
Column Oven
-Dimensions: 28 cm (w) x 20 cm (d) x 28 cm (h)
-Temperature range: ambient +4 °C to 450 °C
-With liquid N2: -99 °C to 450 °C
-With liquid CO2: -65 °C to 450 °C
-Temperature program ramps/holds: 7/8
-Maximum temperature ramp rate: 100 °C/min for all voltages
-Cool down rate: 400 °C to 50 °C in 4.5minutes
-Temperature set-point resolution: 1 °C
Injector Options
-Maximum injectors: three operating concurrently
-Pneumatics: manual or electronic flow control (EFC)
-Columns: capillary columns standard with optional packed column adapter
-Injectors
-CP-1177Split/Splitless
-1079 Programmable Temperature Vaporizing (PTV)
-1061 Flash Megabore/Packed
-1041On-Column Megabore/Packed
CP-1177 Split/Splitless
-Pressure range: 0-100 psi
-Total flow: 500 rrillrnin at 10 psi
-Maximum temperature: 450 °C
-Split range: 1-10,000 (column dependent)
1079 Programmable Temperature Vaporizing (PTV)
-Pressure range: 0-100 psi
-Total flow: 500 mL/min at 10 psi
-Temperature range
–99 °C to 450°C liquid N2
–65 °C to 450°C liquid CO2
-Maximum temperature ramp rate: 180 °C/min
-Temperature ramps: 4
-Split range: 1-10,000 (column dependent)
-Operational modes
-Temperature ramped splitless
-Coldon-column
-Large Volurne Injection
-Split and splitless
-ChromatoProbe solid sample introduction:
optional
1061 Flash Megabore/Packed
-Pressure range: 0-100 psi
-Total Flow:50 mL/min (Type 3 EFC)
500mL/min (Type 4 EFC)
-Maximum temperature: 450 °C
1041 On-Column Megabore/Packed
-Pressure range: 0-100 psi
-Total Flow:50 mL/min (Type 3 EFC)
500mL/min (Type 4 EFC)
-Maximum temperature: 450 °C
FID
-Maximum temperature: 450 °C
-Detectivity:2 pg C/see
-Linear dynamic range: 107
-Patented ceramic -Flame tip: standard
-Flame-out detection/auto re-ignition: standard
TSD
-Maximum temperature: 450 °C
-Detectivity:
N: 100 fg N/sec (Azobenzene)
P: 100 fg P/sec (Malathion)
-Maximum temperature: 450 °C
-Linear dynamic range:
N: 105
P: 104
-Self-aligning bead: standard
Combi PAL AutoSampler
-Sample trays: two standard and expandable to four
-Tray types: 98 x 2mL vials; 200 x 1 mL vials;
32 x 10 m 1120 mL vials; and 96-well plates
-Dual and duplicate mode: standard
-Internal standard: standard
-Modes of Operation: liquid, standard; heated headspace, optional;and SPME, optional
-Sample heating and cooling: standard
-Optional modules:additional sample trays, micro-well plate holders, wach station, SPME fiberbake-out station, dilutor, barcode readers, and flowcell